Build the operable partition scope estimate review record
Use floor plans, reflected ceiling plans, sections, structural details, finish schedules, and the partition specification. Record opening width and height, panel type, stacking location, track layout, pass door, and operating method. Identify curves, intersections, and paired openings separately.
Use the interior partition takeoff review as a related control. Keep this review tied to its own source population and cost lines.
Check quantities and scope boundaries
List panels, track, carriers, seals, trim, pockets, closures, controls, and documented accessories. Keep structural support, backing, ceiling closures, floor preparation, electrical power, and finish work assigned to the package shown in the documents.
AACE recommended practices provide general estimating references. The controlled project documents and approved estimate basis govern this review.
| Review field | Required record |
|---|---|
| Population | Location, type, and source |
| Quantity | Measured basis and unit |
| Interface | Included work and package owner |
| Disposition | Estimate treatment and reviewer |
Reconcile the package before release
Reconcile the partition with structural framing, ceilings, lights, sprinklers, air devices, flooring, wall pockets, and egress openings. Confirm field measurement, engineering, installation, adjustment, and acoustic testing requirements before estimate release. Record unresolved assignments in the construction scope gap matrix and preserve the approved disposition with the estimate revision.